PowerCross™ .018 PTA Balloon Catheter
Experience the power of refined PUSHABILITY.
Introducing PowerCross™, the next generation in PTA Balloon technology from ev3. Experience the power of refined pushability with the enhanced OTW .018" balloon designed to cross smoothly and deflate quickly.
Ultra-low Crossing Profile
Marker Bands
Improved Deliverability
Ultra-low Crossing Profile
- ThermoFlex™ Balloon Material designed for strength and crossability
- Bevel 360™ Tip provides ultra smooth transition from wire to tip

Marker Bands
- Features two additional marker bands centered on both the 150 and 200 mm balloons to provide additional visibility

Improved Deliverability
- Robust catheter design optimizes pushability and tracking
- CrossCoat™ Hydrophilic Coating reduces friction
- Large internal lumen design facilitates reduced deflation times
- Low deflation times for 200 mm length balloons on long 150 cm shaft
| Product Spec | |||||||
| Product Code 150 cm catheter length |
Product Code 90 cm catheter length |
Balloon Size Diameter (mm) |
Balloon Size Length (mm) |
NP (atm) |
RBP (atm) |
Recommended Introducer Sheath (F) |
|---|---|---|---|---|---|---|
| AB18W020020150 | AB18W020020090 | 2 | 20 | 8 | 14 | 4 |
| AB18W020040150 | AB18W020040090 | 2 | 40 | 8 | 14 | 4 |
| AB18W020100150 | AB18W020100090 | 2 | 100 | 8 | 14 | 4 |
| AB18W020150150 | AB18W020150090 | 2 | 150 | 8 | 14 | 4 |
| AB18W020200150 | AB18W020200090 | 2 | 200 | 8 | 14 | 4 |
| AB18W025020150 | AB18W025020090 | 2.5 | 20 | 8 | 14 | 4 |
| AB18W025040150 | AB18W025040090 | 2.5 | 40 | 8 | 14 | 4 |
| AB18W025100150 | AB18W025100090 | 2.5 | 100 | 8 | 14 | 4 |
| AB18W025150150 | AB18W025150090 | 2.5 | 150 | 8 | 14 | 4 |
| AB18W025200150 | AB18W025200090 | 2.5 | 200 | 8 | 14 | 4 |
| AB18W030020150 | AB18W030020090 | 3 | 20 | 8 | 14 | 4 |
| AB18W030040150 | AB18W030040090 | 3 | 40 | 8 | 14 | 4 |
| AB18W030060150 | AB18W030060090 | 3 | 60 | 8 | 14 | 4 |
| AB18W030080150 | AB18W030080090 | 3 | 80 | 8 | 14 | 4 |
| AB18W030100150 | AB18W030100090 | 3 | 100 | 8 | 14 | 4 |
| AB18W030120150 | AB18W030120090 | 3 | 120 | 8 | 14 | 4 |
| AB18W030150150 | AB18W030150090 | 3 | 150 | 8 | 14 | 4 |
| AB18W030200150 | AB18W030200090 | 3 | 200 | 8 | 14 | 4 |
| AB18W040020150 | AB18W040020090 | 4 | 20 | 8 | 14 | 4 |
| AB18W040040150 | AB18W040040090 | 4 | 40 | 8 | 14 | 4 |
| AB18W040060150 | AB18W040060090 | 4 | 60 | 8 | 14 | 4 |
| AB18W040080150 | AB18W040080090 | 4 | 80 | 8 | 14 | 4 |
| AB18W040100150 | AB18W040100090 | 4 | 100 | 8 | 14 | 4 |
| AB18W040120150 | AB18W040120090 | 4 | 120 | 8 | 14 | 4 |
| AB18W040150150 | AB18W040150090 | 4 | 150 | 8 | 14 | 4 |
| AB18W040200150 | AB18W040200090 | 4 | 200 | 8 | 14 | 4 |
| AB18W050020150 | AB18W050020090 | 5 | 20 | 8 | 14 | 4 |
| AB18W050040150 | AB18W050040090 | 5 | 40 | 8 | 14 | 4 |
| AB18W050060150 | AB18W050060090 | 5 | 60 | 8 | 14 | 5 |
| AB18W050080150 | AB18W050080090 | 5 | 80 | 8 | 14 | 5 |
| AB18W050100150 | AB18W050100090 | 5 | 100 | 8 | 14 | 5 |
| AB18W050120150 | AB18W050120090 | 5 | 120 | 8 | 14 | 5 |
| AB18W050150150 | AB18W050150090 | 5 | 150 | 8 | 14 | 5 |
| AB18W050200150 | AB18W050200090 | 5 | 200 | 8 | 14 | 5 |
| AB18W060020150 | AB18W060020090 | 6 | 20 | 8 | 14 | 4 |
| AB18W060040150 | AB18W060040090 | 6 | 40 | 8 | 14 | 5 |
| AB18W060060150 | AB18W060060090 | 6 | 60 | 8 | 14 | 5 |
| AB18W060080150 | AB18W060080090 | 6 | 80 | 8 | 14 | 5 |
| AB18W060100150 | AB18W060100090 | 6 | 100 | 8 | 14 | 5 |
| AB18W060120150 | AB18W060120090 | 6 | 120 | 8 | 14 | 5 |
| AB18W060150150 | AB18W060150090 | 6 | 150 | 8 | 14 | 5 |
| AB18W060200150 | AB18W060200090 | 6 | 200 | 8 | 14 | 6 |
The PowerCross 0.018" OTW PTA Dilatation Catheter is intended to dilate stenoses in the iliac, femoral, ilio-femoral, popliteal, infra-popliteal, and renal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for stent post-dilatation in the peripheral vasculature.
Indications, contraindications, warnings and instructions for use can be found in the product labeling supplied with each device. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.