Visi-Pro® Balloon-Expandable Biliary Stent System
Visible Precision
This Visi-Pro® Biliary Stent is a balloon expandable biliary stent made from a stainless steel tube that is cut into an open lattice design. It has tantalum radiopaque markers at the proximal and distal ends of the stent. The stent is mounted (crimped) onto a tightly-folded balloon catheter and expanded and deployed by inflating the balloon.
Premium Visibility
Solid Radial Strength and Flexibility
Precise Placement
Premium Visibility
- Exclusive 0.035" BE Stent with radiopaque stent markers ensuring visualization during and after stent placement
Solid Radial Strength and Flexibility
- Patented design balances strength and flexibility
Precise Placement
- Precise balloon to stent placement
- Accurate catheter marker alignment
- Progressive stent design delivers minimal shortening
| Product Spec | |||||||
| Visi-Pro™ Baloon-Expandable Biliary Stent System | |||||
| 80 cm Product Catalog number | 135 cm Product Catalog number | Stent Diameter (mm) | Stent Length (mm) | Balloon Length (mm) | Recommended Sheath Size (F) |
|---|---|---|---|---|---|
| PXB35-05-12-080 | - | 5 | 12 | 15 | 6 |
| PXB35-05-17-080 | PXB35-05-17-135 | 5 | 17 | 20 | 6 |
| PXB35-05-27-080 | PXB35-05-27-135 | 5 | 27 | 30 | 6 |
| PXB35-05-37-080 | PXB35-05-37-135 | 5 | 37 | 40 | 6 |
| PXB35-05-57-080 | PXB35-05-57-135 | 5 | 57 | 60 | 6 |
| PXB35-06-12-080 | - | 6 | 12 | 15 | 6 |
| PXB35-06-17-080 | PXB35-06-17-135 | 6 | 17 | 20 | 6 |
| PXB35-06-27-080 | PXB35-06-27-135 | 6 | 27 | 30 | 6 |
| PXB35-06-37-080 | PXB35-06-37-135 | 6 | 37 | 40 | 6 |
| PXB35-06-57-080 | PXB35-06-57-135 | 6 | 57 | 60 | 6 |
| PXB35-07-12-080 | - | 7 | 12 | 15 | 6 |
| PXB35-07-17-080 | PXB35-07-17-135 | 7 | 17 | 20 | 6 |
| PXB35-07-27-080 | PXB35-07-27-135 | 7 | 27 | 30 | 6 |
| PXB35-07-37-080 | PXB35-07-37-135 | 7 | 37 | 40 | 6 |
| PXB35-07-57-080 | PXB35-07-57-135 | 7 | 57 | 60 | 6 |
| PXB35-08-17-080 | PXB35-08-17-135 | 8 | 17 | 20 | 6 |
| PXB35-08-27-080 | PXB35-08-27-135 | 8 | 27 | 30 | 6 |
| PXB35-08-37-080 | PXB35-08-37-135 | 8 | 37 | 40 | 6 |
| PXB35-08-57-080 | PXB35-08-57-135 | 8 | 57 | 60 | 6 |
| PXB35-09-17-080 | PXB35-09-17-135 | 9 | 17 | 20 | 7 |
| PXB35-09-27-080 | PXB35-09-27-135 | 9 | 27 | 30 | 7 |
| PXB35-09-37-080 | PXB35-09-37-135 | 9 | 37 | 40 | 7 |
| PXB35-09-57-080 | PXB35-09-57-135 | 9 | 57 | 60 | 7 |
| PXB35-10-17-080 | PXB35-10-17-135 | 10 | 17 | 20 | 7 |
| PXB35-10-27-080 | PXB35-10-27-135 | 10 | 27 | 30 | 7 |
| PXB35-10-37-080 | PXB35-10-37-135 | 10 | 37 | 40 | 7 |
| PXB35-10-57-080 | PXB35-10-57-135 | 10 | 57 | 60 | 7 |
The Visi-Pro Biliary Stent is intended as a palliative treatment of malignant neoplasms in the biliary tree.
Indications, contraindications, warnings and instructions for use can be found in the product labeling supplied with each device. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.
WARNING: The safety and effectiveness of this device for use in the vascular system have not been established.