Skip to content

Current Section:

Image Title: neuro

Page 'Breadcrumb' Path:

  • Add This

Nexus Detachable Coils

Nexus Detachable Coils are a line of coils that are designed to deliver softness, conformability and durability. Its unique design allows it to be used as a framing and filling coil of complex, amorphic aneurysm as well as satisfying routine coiling needs.
  • The Nexus Tetris 3-D CSR 10 is an innovative starting coil that builds a supportive basket into which additional coils can be deployed.
  • For the filling and finishing stage, the enhanced Nexus Helix SuperSoft CSR Coil allows for safe deployment and increased filling.
Nexus Tetris 3-D CSR (Small)
Product Code Number Diameter(mm) Restrained Length(cm)
X-3-4-T10-TC 3 4
X-4-5-T10-TC 4 5
X-5-10-T10-TC 5 10
X-6-12-T10-TC 6 12
X-7-15-T10-TC 7 15
Nexus Tetris 3-D CSR (Medium)
Product Code Number Diameter(mm) Restrained Length(cm)
X-8-16-T10-TC 8 16
X-9-18-T10-TC 9 18
X-10-20-T10-TC 10 20
Nexus Tetris 3-D CSR (Large)
Product Code Number Diameter(mm) Restrained Length(cm)
X-12-23-T10-TC 12 23
X-14-26-T10-TC 14 26
X-16-29-T10-TC 16 29
X-18-29-T10-TC 18 29
Nexus Multi-Diameter CSR
 
Product Code Number Diameter(mm) Restrained Length(cm)
X-4-10-T10-MD 4 10
X-5-15-T10-MD 5 15
X-6-20-T10-MD 6 20
X-7-30-T10-MD 7 30
X-8-30-T10-MD 8 30
X-10-30-T10-MD 10 30
Nexus Helix Supersoft CSR
 
Product Code Number Diameter(mm) Restrained Length(cm)
X-2-1-T10-HSS 2 1
X-2-2-T10-HSS 2 2
X-2-3-T10-HSS 2 3
X-2-4-T10-HSS 2 4
X-2-6-T10-HSS 2 6
X-2-8-T10-HSS 2 8
X-3-3-T10-HSS 3 3
X-3-4-T10-HSS 3 4
X-3-6-T10-HSS 3 6
X-3-8-T10-HSS 3 8
X-4-4-T10-HSS 4 4
X-4-6-T10-HSS 4 6
X-4-8-T10-HSS 4 8
X-4-10-T10-HSS 4 10
X-5-15-T10-HSS 5 15
X-6-20-T10-HSS 6 20
X-7-30-T10-HSS 7 30
X-8-30-T10-HSS 8 30
X-10-30-T10-HSS 10 30
The Nexus Detachable Coils are intended for the endovascular embolization of intracranial aneurysms that – because of their morphology, their location, or the patient’s general medical condition – are considered by the treating neurosurgical team to be a) very high risk for management by traditional operative techniques, or b) be inoperable. The Nexus™ Detachable Coils are also intended for the embolization of other neurovascular abnormalities, such as arteriovenous malformations and arteriovenous fistulae.

Indications, contraindications, warnings and instructions for use can be found in the product labeling supplied with each device. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.